Both IRC scanners, the Prisma Fit in Sacramento and the Skyra in Davis, are equipped with the same stimulus presentation, response recording, and physiological monitoring systems for human studies.
The visual stimulus presentation systems are designed to present high-resolution in-bore images with the tightly controlled timing needed to record event-related potentials (ERP) simultaneously with fMRI data acquisition. We achieve this with the BOLDscreen 24 LCD for fMRI, by Cambridge Research Systems.
The BOLDscreen has a high-resolution 1920 x 1200 IPS LCD panel with native 8-bit color resolution, providing a true-color 16.7-million-color display and contrast of up to 1000:1. The BOLDscreen is fully MRI compatible. It is mounted at the rear of the bore, where its 24" display provides the maximum field of view, and is viewed through mirrors mounted on the head coil.
Auditory stimuli are presented during scanning through three high-fidelity systems designed for the MR environment: MR confon headphones, Optoacoustics OptoACTIVE SLENDER noise-canceling headphones, and Sensimetrics S14 insert earphones.
The MR confon headphones contain electrodynamic transducers for a broad, flat frequency response, and use construction-grade Peltor earmuffs for passive damping of gradient noise. Because they use electrodynamic rather than pneumatic transduction, they produce sound quality comparable to a home stereo, with an 88 dB signal-to-noise ratio and high channel separation. During a functional MRI session, sounds can be presented at detection-threshold levels between "sparse" acquisitions, or at conversational levels (approximately 75–80 dB) during continuous scanning.
The OptoACTIVE SLENDER two-way noise cancellation system, purchased in 2026 in collaboration with the Center for Mind and Brain, provides active noise cancellation with up to 40 dB reduction of scanner acoustic noise. It supports real-time, full-duplex digital audio communication between participants and operators. Its slim, non-magnetic headset weighs under 100 g, fits within 32- and 64-channel head coils, and has a frequency response of 100 Hz to 8 kHz for clear speech. The headphones are CE MDR-certified and US FDA 510(k)-cleared.
The S14 insert earphones are used when high-quality sound is needed in a restricted space. They use piezoelectric transducers and Comply foam canal tips to achieve both a flat frequency response (100 Hz – 8 kHz) and high attenuation of scanner noise.
The eye-tracking system is the EyeLink 1000 Plus long-range, manufactured by SR Research of Ottawa, Canada. The system includes a dedicated computer running a real-time operating system, a fiber-optic camera, a long-range infrared illuminator, and an MRI-safe mounting system.
The eye tracker is monocular and records at 1000 Hz. The recorded data include X and Y positions, saccade onset and offset times, and pupil size, with an accuracy of 0.25–0.50 degrees, a resolution of 0.05 degrees RMS, and a saccade resolution of 0.25 degrees. At 1000 Hz, real-time data access has a mean delay of 2.2 ms (SD 0.3 ms). The EyeLink has broad software support. The IRC has used the eye tracker in projects with the stimulus presentation software E-Prime, MATLAB, and Presentation.
Investigators use Windows workstations to deliver visual paradigms. Stimulus presentation and button-press response acquisition are controlled by E-Prime (Psychology Software Tools, Inc.), Presentation (Neurobehavioral Systems, Inc.), Psychophysics Toolbox (an open-source toolbox for MATLAB), or PsychoPy (open-source Python).
Participants respond by pressing buttons on specially constructed MRI-compatible fiber-optic devices (fORP by Current Designs). Several response devices are available: 8 buttons (4 in each hand), 5 buttons (single hand), and a joystick. The metal-free response devices are connected by fiber-optic cable to an optoelectronic controller unit.
All of this equipment can also be used with lab-provided laptops running the operating system and software of the lab's choice.
Physiological waveforms from the participant being scanned can be recorded with the BioPac MP 150 system. Available modules include cardiac, respiratory, galvanic skin response, and other physiological signals.
The Siemens Prisma Fit also has a built-in physiological measurement unit (PMU). Using MRI-safe Bluetooth transmitters, the PMU can capture pulse oximetry and respiratory data at 20 ms resolution, and 3-lead EKG data at 2.5 ms resolution.
The mock MRI system simulates the environment of an MRI scanner. It consists of a mock-up of an MRI system, non-functioning RF coils, and a built-in speaker system that plays back recordings of pulse sequence sounds. It also includes the same visual and auditory stimulus presentation systems used in the actual MRI environment.
Using the mock MRI system, potential participants can be acclimated to the scanner and trained for fMRI studies. A headphone-mounted motion detector teaches participants to notice their own head motion, which must be minimized during an actual scan.